ELECTRICAL / GAS CONNECTIONS
14
GAS REQUIREMENTS
Verify the type of gas supplied to the location. The
range are shipped from the factory set up and
adjusted for natural gas or LP (propane),depending on
specific model ordered. The unit CANNOT be
converted.
NATURAL GAS
Connection: 1/2 N.P.T. Minimum 5/8 dia. flex
line.
Pressure: 6to 14W.C.
LP GAS
Connection: 1/2 N.P.T. Minimum 5/8 dia. flex
line.
Pressure: 11to 14W.C.
A regulator is required at the LP source to provide a
maximum of 14W.C. to the range regulator.
HOOK-UP
A manual valve must be installed external to the appliance,in an accessible location from the front for
the purpose of shutting off the gas supply. The supply line must not protrude beyond the back of the
unit. Make sure the gas supply is turned off at the wall valve before connecting the appliance.
The gas supply connections should be made by a qualified technician and in accordance with local
codes or ordinances. In the absence of a local code,the installation must conform to the National Fuel
Gas Code ANSI 223.-1988, latest edition.
NOTE: The flex line for the gas supply must be metal and be approved by an approved certifying
agency (AGA,CGA,CSA,or UL). Never use a hose made of rubber or other synthetic material,as the heat
may cause the hose to melt and develop leaks.
CAUTION:
The appliance must be isolated from the building’s gas supply piping system
by closing its individual manual shut-off valve during any pressure testing of
the gas supply piping system at test pressures equal to or less than 1/2 psig
(3.5kPa.).
The appliance and its individual shut-off valve must be disconnected from
the gas supply piping system during any pressure testing of the system at the
test pressures in excess of 1/2 psig (3.5kPa.). When checking the manifold gas
pressure, the inlet pressure to the regulator should be at least 7.0” W.C. for
natural gas or 12.0” for LP.
Fig. 14 All RGS Models
Ele
c
2" Maximum
Protrusion from Wall
for Gas Supply
Gas Supply
Flex Line to Range
Manual Shut-Off
Valve must be
Easily Accessible
Gas Supply
Flex Line To Range
Manual Shut-Off
Valve Must Be
Easily Accessible
2 Maximum
Protrusion From
Wall For Gas
Supply