INSTALLATION INSTRUCTIONS
Fig.9
Internal blower installation in one of the following three options:
Option 1: Internal blower, front installation for venting left, right or down
Disconnect the cable from inside the downdraft unit. Plug in that same cable
from the downdraft unit into the internal blower Fig.7.
Turn the venting collar on the internal blower box to the desired direction – left,
right ordown.
Mount the internal blower box to the housing using four screws Fig.8.
Continue to the ‘Prepare for electrical connection’ section on page 21.
Option 2: Internal blower, front installation for venting to the rear
When venting to the rear with the internal blower mounted on the front of the
downdraft unit, repositioning of the blower box is required.
Remove the two screws and take the blower out of the internal blower box Fig.9.
Remove the small cover on the back of the downdraft unit Fig.10.
Mount the blower on the front of the downdraft unit using two screws while
positioning the vent collar in the opening of the cover Fig.11.
BACK
Fig.10
FRONT
Fig.11
FRONT
Fig.8Fig.7